Greencisco Industrial Co., Ltd.

Shore frequency converter (380V or 400V or 10KV ) 60KVA-400KVA

Shore frequency converters are specially used in ports, yacht,dockyard fitting-out berth, ships and ocean drilling platforms

Characteristics

Introduction

Shore frequency converters are specially used in ports, dockyard fitting-out berth, ships and ocean drilling platforms with outdoor harsh environments which need outdoor frequency conversion variables with high reliability of power supply. This series of products adopt full sealed three layers of insulation pipeline with full air conditioning circulation protection. Inside of equipment environment is completely isolation with the outside world. Equipment tank protection level IP66, air conditioning system is level IP56, fully meet the shore wharf, ships and drilling platforms with any harsh outdoor environments. A complete set of equipment in accordance with the standard container box shape design, easy to transport and move often. 

Feature

●Using the full sealed air conditioning cooling system with three insulation layer tank to ensure that the equipment is under good protection.

●Adopting the latest instantaneous voltage waveform control technology, output voltage fluctuation≤0.5V,when 100% load, the output voltage fluctuation less than 3% and recover to the rated output voltage value in 0.5 wave cycle.

●Adopting technology of pure sine inverter output filter. Reduce the output impedance of the sinusoidal filter and improve the quality of the output power.

●Driven by our module with signal master-slave synchronization parallel technology. Which can realize parallel working of many shore variable power equipments without current circulation interference.

●Using the power switching devices which is made by Germany, DSP core is made by USA with 5Mhz optical fiber driver transmission mode. The inverter modulation method adopts the latest SVPWM space vector pulse width modulation.

Specification

Model

SFC-60

SFC-100

SFC-120

SFC-150

SFC-200

SFC-250

SFC-300

SFC-350

SFC-400

Capacity(KVA)

60

100

120

150

200

250

300

350

400

Input Voltage400VAC±10%/10KV±10%,3phases,can be customized special voltage input according to customers'requirements
Frequency50Hz±10%/60Hz±10%
Phase3phases+3wires or 3phases+5 wires
Rectifier6pluses or PWM
Power factor6pluses>0.95; PWM>0.99
THDi<35%(6pluses at 100%load)or<5% (PWM at 100% load)
Output Voltage440VAC, 6.6KV (can be customized special voltage output)
Capacity

60KVA

100KVA

120KVA

150KVA

200KVA

250KVA

300KVA

350KVA

400KVA

Phase3phases+3wires or 3phases+4wires
Voltage Stabilizing<0.5V at static; <±1%(dynamic,0-100%load)
Frequency50Hz or 60Hz (precision:0.01)
Frequency stabilizing<0.01%(0-100%load)
Overload ability125% for 1minute; 150% stop output;can withstand 3 times of instant impact
Total harmonic distortion of output voltage THDu≤1%(no load or line load )
Peak coefficient of output voltage CF1.4+0.1(No load)
Three phase output voltage imbalance<1%
Phase angle of three-phase output voltage120°(±0.1°)
Efficiency≥95%(100%load)
Inverter main circuit topologyIGBT modules constitutes a three-phase full-bridge inverter circuit
Inverter adjustment methodSVPWM space vector pulse width modulation method
Voltage stabilizing controlInstantaneous voltage waveform feedback control method
Inverter switch frequency3.6KHZ~6KHZ
PWM Drive Transmission Mode5MHZ fiber drive transmission
Master processor150NHz
Sinusoidal filtering methodThree-stage sinusoidal filter at output of inverter
DisplayLCD display or digital display
Compressive strengthLow pressure: 2500V/AC, 1 minute, no breakdown fire phenomenon(leakage current 10mA); High Pressure: 42 KV/AC, 1 minute, should not break through the fire phenomenon
Cold insulation resistance≥100MΩ
Noise≤55dB(A)
EnvironmentAmbient temperature is -5 °C to +45 °C, and the relative humidity is 0 to 95 °C,Working for 24 hours at 100% full load,the temperature in the equipment cabin is in the range of 25 °C ± 1 °C
Protection ClassIP32
Coolingforced fan
Elevation<1000M
Software Application MacroSelection of marine shore frequency converter application macros, analog power grid application macros, inverter test macros, electric motor macros and ex-factory test macros and transformer test macros
ProtectionPhase deficit(three-phase imbalance), undervoltage, overvoltage, overcurrent, short circuit, DC bus overvoltage, frequency power supply trip protection. (protection threshold can be set)
Dimension(LXWXH)mm

800x650x1800

1100x1000x2000

2000x1200x2200

2900x1500x2200

Weight(KGS)

400

900

1000

1200

1300

1500

1800

2000

2100