欢迎访问格林思科实业有限公司官方网站

IP56 Marine frequency converter (380V or 400V or 10KV) 40KVA-350KVA

Marine frequency converter(380V or 400V or 10KV ) are specially used in ports, dockyard fitting-out berth, shipbuilding,shiprepairing and oil drilling platforms,which is made by world-class technology of ours.

产品详情

Introduction

Marine frequency converters are specially used in ports, dockyard fitting-out berth, ships and ocean drilling platforms with outdoor harsh environments which need outdoor frequency conversion variables with high reliability of power supply. This series of products adopt full sealed three layers of insulation pipeline with full air conditioning circulation protection. Inside of equipment environment is completely isolation with the outside world. Equipment tank protection level IP56, fully meet the shore wharf, ships and drilling platforms with any harsh outdoor environments. A complete set of equipment in accordance with the standard container box shape design, easy to transport and move often. 

Feature

●Using the full sealed air conditioning cooling system with three insulation layer tank to ensure that the equipment is under good protection.

●Adopting the latest instantaneous voltage waveform control technology, output voltage fluctuation≤0.5V,when 100% load, the output voltage fluctuation less than 3% and recover to the rated output voltage value in 0.5 wave cycle.

●Adopting technology of pure sine inverter output filter. Reduce the output impedance of the sinusoidal filter and improve the quality of the output power.

●Driven by our module with signal master-slave synchronization parallel technology. Which can realize parallel working of many shore variable power equipments without current circulation interference.

●Using the power switching devices which is made by Germany, DSP core is made by USA with 5Mhz optical fiber driver transmission mode. The inverter modulation method adopts the latest SVPWM space vector pulse width modulation.

Specification

Model

SFC-40

SFC-50

SFC-100

SFC-120

SFC-150

SFC-200

SFC-250

SFC-300

SFC-350

Capacity(KVA)

40

50

100

120

150

200

250

300

350

Input Voltage380/400VAC±10%/10KV±10%,3phases,can be customized special voltage input according to customersrequirements
Frequency50Hz±10%/60Hz±10%
Phase3phases+3wires
Rectifier6pluses or PWM
Power factor6pluses>0.95; PWM>0.99
THDi<35%(6pluses at 100%load)or<5% (PWM at 100% load)
Output Voltage440VAC, 6.6KV (can be customized special voltage output)
Current

440V/52A

440V/65A

440V/131A

440V/157A

440V/196A;

6.6KV/131A

440V/262A;

6.6KV/175A

440V/328A;

6.6KV/218A

440V/393A;

6.6KV/262A

440V/459A;

6.6KV/306A

Capacity

40KVA

50KVA

100KVA

120KVA

150KVA

200KVA

250KVA

300KVA

350KVA

Phase3phases+4wires
Voltage Stabilizing<0.5V at static; <±1%(dynamic,0-100%load)
Frequency50Hz or 60Hz (precision:0.01)
Frequency stabilizing<0.01%(0-100%load)
Overload ability125% for 1minute; 150% stop output;can withstand 3 times of instant impact
Total harmonic distortion of output voltage THDu≤1%(no load or line load )
Peak coefficient of output voltage CF1.4+0.1(No load)
Three phase output voltage imbalance<1%
Phase angle of three-phase output voltage120°(±0.1°)
Efficiency≥95%(100%load)
Inverter main circuit topologyGermany SKIIP fourth-generation half-bridge IPM intelligent power module constitutes a three-phase full-bridge inverter circuit
Inverter adjustment methodSVPWM space vector pulse width modulation method
Voltage stabilizing controlInstantaneous voltage waveform feedback control method
Inverter switch frequency3.6KHZ~6KHZ
PWM Drive Transmission Mode5MHZ fiber drive transmission
Master processor150NHz
Sinusoidal filtering methodThree-stage sinusoidal filter at output of inverter
DisplayLCD display or touch screen display
Input displayDisplay input power three-phase line(phase) voltage, frequency, three-phase line current, input voltage harmonic analysis, visual power, active power, reactive power, power factor, active power meter, reactive power measurement. (Display and measurement accuracy is 0.5)
Output displayDisplay output power three-phase line(phase) voltage, frequency, three-phase line current, output voltage harmonic analysis, visible power, active power, reactive power, power factor, active power measurement, reactive power measurement. (display and measurement accuracy 0.5)
System Parameters DisplaySystem operation time, DC bus voltage, power module output current, inverter switch frequency, output voltage setting value, output frequency setting value, input Transformer temperature, rectifier
Temperature, three-phase power module temperature, sinusoidal filter temperature, output Transformer temperature.
Fault displayShow fault alert information graphically and permanently record all running data when a failure occurs for future analysis of the failure
Operation displayDisplay information such as system state, operation prompt, fault location and handling method to facilitate operators operation and maintenance of equipment
Drawings Data DisplayEach set of variable frequency power supply is permanently stored the drawings, instructions and other technical data of the variable frequency power supply, and it is very convenient to consult
Compressive strengthLow pressure: 2500V/AC, 1 minute, no breakdown fire phenomenon(leakage current 10mA); High Pressure: 42 KV/AC, 1 minute, should not break through the fire phenomenon
Cold insulation resistance≥100MΩ
Noise≤55dB(A)
EnvironmentAmbient temperature is -5 °C to +45 °C, and the relative humidity is 0 to 95 °C,Working for 24 hours at 100% full load,the temperature in the equipment cabin is in the range of 25 °C ± 1 °C
Protection ClassIP66 for equipment, fully sealed insulation; IP56 for Air conditioning
CoolingAir conditioner
Elevation<1000M
ProtectionInput power supply phase sequence, phase deficit(three-phase imbalance), undervoltage, overvoltage, overcurrent, short circuit, DC bus overvoltage (protection threshold can be set )
The output power supply produces phase deficiency, undervoltage, overvoltage, Overflow, short circuit, output voltage harmonic overvalue, (protection threshold can be set )
Transformer temperature, sinusoidal filter temperature, rectifier temperature, IPM power module exceeds normal operating temperature, frequency converter power supply trips protection. (Temperature value can be set)
When the transformer temperature and the sinusoidal filter temperature reach the fan starting temperature, the corresponding fan is started for forced wind cooling. (Temperature value can be set)
Considering the control of different power loads, when the output load capacity reaches any setted value, the sound and light pre-alarm signal is issued.After the overload alarm signal is issued for 1 minute, variable frequency power supply stops to be protection(the setting can be adjustable)
Dimension(LXWXH)mm

1000x1200x2200

1000x1500x2200

1800x1800x2200

1800x1800x2200

Weight(KGS)

200

400

500

550

600

800

1000

1200

1400